| Brand |
Rosemount |
|---|
| Rosemount MS Magnetic Sensor MS120 for Slurry Applications, 12 inch (DN300) |
| Reference Accuracy |
| Line Size |
| Liner Material Options |
| Electrode Options |
| Flange Options |
| Approvals |
| Enclosure Type |
| Compatibility |
| ±0.25% with optional ±0.15% high accuracy |
| 3” (80mm) to 36” (900mm) |
| PTFE, PFA+, Polyurethane, Neoprene, Linatex Natural Rubber, Adiprene |
|
|
|
| Type 4X |
| IP66, IP67, IP68, IP75 |
| 8782 Slurry Transmitter for optimum performance in high noise applications |
Rosemount MS Magnetic Sensor MS120 for Slurry Applications, 12 inch (DN300)
- Capability to handle extremely noisy applications while delivering stable flow outputs better than a standard magnetic flow meter when paired with the 8782 transmitter
- Increased signal strengths allows for more precise flow measurement and reduce process variability even in hard to measure flows when paired with the 8782 transmitter
- Reduce sensor inventory with a dual calibration option
- Ensure reliability in the harshest environments with an all-welded sensor housing
- Guard against installation damage and leading-edge wear with optional lining protectors
- Avoid process shutdown with a removable and replaceable terminal block that enables repairs in the field
- Capture any potential process fluid leakage with optional secondary containment compartments
- Minimize maintenance and repair with an obstructionless design featuring no moving parts, ideal for metering conductive slurries
- Pair the MS Slurry Sensor with the 8782 Slurry Transmitter for optimum performance in high noise applications.
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
- Continually monitor meter health and performance without stopping the process with Smart Meter Verification
- Prevent moisture ingress with dual-compartment transmitter housing
- Improve process management with advanced Digital Signal Processing
- Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
- Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
- Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
- Simplify adjustments in hazardous environments without removing the cover using optical switches for configuration
- Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor