| Rosemount 8721020 Hygienic Magnetic Flow Meter Sensor, 2 Inch (DN50) | |
| Accuracy | Up to 0.25% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.5% over 40:1 flow turndown |
| Line Sizes | ½-4 inch (15-100 mm) |
| Liner Materials | PFA |
| Electrode Materials | 316L Stainless Steel, Nickel Alloy, Platinum |
| Process Connections | Tri-Clamp® Sanitary Coupling IDF Sanitary Coupling (screw type) Weld Nipple DIN 11851 (Imperial and Metric) DIN 11864 (-1 and -2 Form A) SMS 1145 DEN US 50 Weld Nipple |
| Product Certifications | 3-A, EHEDG Type EL, PMO (M-b-350) |
| Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters | |
| Sensor compatibility | Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers. |
| Transmitter coil drive current | 500mA |
| Flow rate range | Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s). |
| Conductivity limits | Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater. |
| Power supply |
|
Rosemount 8721020 Hygienic Magnetic Flow Meter Sensor, 2 Inch (DN50)
- Lightweight, compact stainless steel design makes installation easy
- Rely on FDA-approved materials including 3-A finish certified by EHEDG for use in Grade A milk
- Fully-welded meter body design allow for safety in hygienic applications
- Sensor is CIP/SIP cleanable and the sensor I.D. matches the process piping to eliminate hard-to-clean step changes
- Satisfy virtually any requirement with a variety of available sanitary process connections
- Better facilitate inspection and maintenance with easily accessed process gaskets
- Cut costs and improve efficiency with an obstructionless design featuring no moving parts to maintain or repair
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
- Continually monitor meter health and performance without stopping the process with Smart Meter Verification
- Prevent moisture ingress with dual-compartment transmitter housing
- Improve process management with advanced Digital Signal Processing
- Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
- Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
- Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
- Simplify adjustments in hazardous environments without removing the cover using optical switches for configuration
Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor