1/5
${data.index + 1}/${data.total}
Description
| Brand |
Rosemount |
|---|
| Rosemount 871115F Wafer Magnetic Flow Meter Sensor, 0.15 Inch (DN4) | |
| Accuracy | Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown |
| Line Sizes | 0.15-8 inch (4-200mm) |
| Liner Materials | ETFE, PTFE, and PFA |
| Electrode Materials | 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium. Consult factory for additional material options |
| Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters | |
| Sensor compatibility | Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers. |
| Transmitter coil drive current | 500mA |
| Flow rate range | Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s). |
| Conductivity limits | Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater. |
| Power supply |
|
Rosemount 871115F Wafer Magnetic Flow Meter Sensor, 0.15 Inch (DN4)
- Cut costs with a flangeless construction for minimum size and weight
- Compact shape is ideal for installation in locations with limited amount of straight run pipe
- Suit any process application with available rugged liner options and standard, grounding and bullet-nose electrodes
- Simplify installation with a lightweight, flangeless design
- Eliminate gaskets and prevent moisture ingress with an all-welded sensor
- Minimize maintenance and repair with an obstructionless design featuring no moving parts
- Avoid process shutdown with a removable and replaceable terminal block that enables repairs in the field
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
- Continually monitor meter health and performance without stopping the process with Smart Meter Verification
- Prevent moisture ingress with dual-compartment transmitter housing
- Improve process management with advanced Digital Signal Processing
- Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
- Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
- Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
- Simplify adjustments in hazardous environments without removing the cover using optical switches for configuration
- Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor