Rosemount MS Magnetic Sensor MS200 for Slurry Applications, 20 inch (DN500)
Reference Accuracy ±0.25% with optional ±0.15% high accuracy
Line Size 3” (80mm) to 36” (900mm)
Liner Material Options PTFE, PFA+, Polyurethane, Neoprene, Linatex Natural Rubber, Adiprene
Electrode Options
  • Material: 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium
  • Type: Standard, Bullet, Flat
  • Optional 3rd electrode for grounding
Flange Options
  • Connections: Slip-on, weld-neck, grooved coupling
  • Ratings: ASME Class 150 – 2500, EN-1092 PN10 – PN40, AS2129 Table D and E, JIS B2220 10K – 40K, AS4087 PN16 – PN35
  • Materials: Carbon Steel, 304/304L SST, 316/316L SST
  • Additional flange ratings and materials may be available upon request
Approvals
  • Ordinary Locations
  • ATEX Non-Sparking; Dust
  • Class I Div 2; Dust
  • Class I Zone 2; Dust
  • IECEx Non-Sparking; Dust
  • ATEX increased safety; Dust
  • Class I Zone1; Dust
  • IECEx Increase Safety; Dust
  • Higher level approvals include Intrinsically Safe Electrodes
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
Compatibility
  • 8782 Slurry Transmitter for optimum performance in high noise applications
  • 8712EM and 8732EM (remote mount only) for standard magnetic flow meter performance
  • Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers.
Transmitter Details
  • Transmitter coil drive current: 500mA
  • Flow rate range: Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).
  • Conductivity limits: Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.
  • Power supply: 90 – 250VAC, 50/60Hz or 12 – 42VDC
  • Line power fuses: 90-250VAC systems: 1A, 250V, I2t, 1.5 A2s Rating, Fast Acting; 12-42VDC systems: 3 Amp, 250V, I2t, 14 A2s Rating, Fast Acting; Line power fuses: 15W maximum – DC, 40VA maximum – AC
  • Switch-on current: AC: Maximum 35.7A (< 5ms) at 250VAC, DC: Maximum 42A (< 5ms) at 42VDC

 

Rosemount MS Magnetic Sensor MS200 for Slurry Applications, 20 inch (DN500)

 

  • Capability to handle extremely noisy applications while delivering stable flow outputs better than a standard magnetic flow meter when paired with the 8782 transmitter
  • Increased signal strengths allows for more precise flow measurement and reduce process variability even in hard to measure flows when paired with the 8782 transmitter
  • Reduce sensor inventory with a dual calibration option
  • Ensure reliability in the harshest environments with an all-welded sensor housing
  • Guard against installation damage and leading-edge wear with optional lining protectors
  • Avoid process shutdown with a removable and replaceable terminal block that enables repairs in the field
  • Capture any potential process fluid leakage with optional secondary containment compartments
  • Minimize maintenance and repair with an obstructionless design featuring no moving parts, ideal for metering conductive slurries
  • Pair the MS Slurry Sensor with the 8782 Slurry Transmitter for optimum performance in high noise applications.

 

Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters

 

  • Continually monitor meter health and performance without stopping the process with Smart Meter Verification
  • Prevent moisture ingress with dual-compartment transmitter housing
  • Improve process management with advanced Digital Signal Processing
  • Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
  • Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
  • Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
  • Simplify adjustments in hazardous environments without removing the cover using optical switches for configuration
  • Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor

 

Get a quote