1/1
${data.index + 1}/${data.total}
Description
| Brand |
Rosemount |
|---|
| Specifications | Rosemount 8705020 Flanged Magnetic Flow Meter Sensor, 2 Inch (DN50) |
|---|---|
| Accuracy | Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown |
| Line Sizes | ½-36 inch (15-900 mm) |
| Liner Materials | PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber, Consult factory for additional material options |
| Electrode Materials | ASME B16.5 Class 150-2500DIN PN 10-40AS 2129 Table D and EAWWA C207 Table 3 Class D (30-36 inch only) |
| Specifications | Rosemount 8712E Magnetic Flow Meter Transmitter |
|---|---|
| Accuracy | Up to ±0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, ±0.25% over 40:1 flow turndown. |
| Diagnostic | In Situ Meter Verification, Grounding & Wiring Fault Detection, High Process Noise Detection, Tunable Empty Pipe Detection, Transmitter Fault Detection, Sensor Fault Detection |
| Compatibility | All Rosemount manufactured Sensors: 8705, 8711, 8721, 8707 Universal capabilities allow E-Series transmitters to be compatible with AC and DC powered sensors from other manufacturers. |
| Power Supply | 90-250 VAC, 50-60 Hz or 12-42 VDC. |
| Power consumption | 15 W maximum – DC 40 VA maximum – AC |
| Enclosure Rating | 8712E: Type 4x, IP66 |
Rosemount 8705020 Flanged Magnetic Flow Meter Sensor, 2 Inch (DN50)
- For maximum protection, a fully welded sensor housing provides a hermetic seal
- Avoid process shutdown with a removable and replaceable terminal block that enables repairs in the field
- Capture any potential process fluid leakage with optional secondary containment compartments to surround electrodes
- Ensure reliability in the harshest environments with an all-welded sensor housing
- Guard against installation damage and leading-edge wear with an optional lining protector
- Minimize maintenance and repair with an obstructionless design featuring no moving parts
Rosemount 8712E Magnetic Flow Meter Transmitter
- Intuitive Local Operator Interface with dedicated keys for ease of use
- Maximize uptime with Smart Meter Verification which monitors meter health and performance without stopping the process
- Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
- Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
- Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
- Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor