rosemount,5301HA1H1N4AM00158CBNAM1P1C1Q4Q8S3SW2J0 | Rosemount 5300 Level Transmitter | 5300 Series

Part Number: 5301HA1H1N4AM00158CBNAM1P1C1Q4Q8S3SW2J0

100% Brand New & Original
1-Year Warranty Included
Full Range of Models
Expert Engineer Support

Description

Part Number: 5301HA1H1N4AM00158CBNAM1P1C1Q4Q8S3SW2J0

Model: 5300 Level Transmitter
Manufacturer: Rosemount
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Ordering Information

Model 5301 Guided Wave Radar Liquid Level or Interface Transmitter (interface available for fully submerged probe)
Signal output H 4-20 mA with HART communication (default output from factory is HART 5, add option code HR7 for HART 7)
Housing material A Polyurethane-covered Aluminum (Aluminum alloy A360, maximum 0.6 percent Cu)
Conduit / cable threads 1 ½ – 14 NPT, 1 plug included
Operating temperature and pressure H(1)(2) Design and operating temperature:
-76 to 752 °F (-60 to 400 °C)
-15 to 5000 psig (-1 to 345 bar)
Material of construction: Process connection / probe 1 316/316L/EN 1.4404
Sealing O-ring material N(3) None
Probe type 4A Description: Rigid Single Lead (8 mm)
Process connections: Flange / 1- in.(4), 1½-in., 2- in.(4) Thread / Tri ClampProbe lengths: Min: 1 ft. 4 in. (0.4 m), Max: 9 ft. 10 in. (3 m)
Probe length units M Metric (meters, centimeters)
Total probe length (feet/m) 001
Total probe length (inch/cm) 58
Process connection – size / type CB 4-in. Class 300, RF (Raised Face Type)
Hazardous locations certifications NA No Hazardous Locations Certifications
Display M1 Integral digital display
Hydrostatic testing P1 Hydrostatic testing, including certificate
Factory configuration C1 Factory configuration per Configuration Data Sheet
Special quality assurance Q4 Calibration data certificate
Material traceability certification Q8 Material traceability certification consistent with ISO10474-3.1:2013 / EN10204-3.1:2004
Centering discs S3(5) Description: 3-in. Centering disc
Outer diameter: 2.7 in. (68 mm)
SW2
J0
  1. Requires option None for sealing (no O-ring).
  2. For applications where a large amount of contamination is present a standard or high pressure seal should be used, if process conditions allow.
  3. Requires Operating Temperature and Pressure code H, P, or C.
  4. Only available with Operating Temperature and Pressure code S.
  5. Available for SST, Alloy C-276, Alloy 400, Alloy 825, and Duplex 2205 probes, type 2A, 4A, 4B, 4S, and 5A. Same disc material as probe material.
  • Estimated Lead Time: 8 – 10 Weeks
  • Shipping Weight: 25 Kg

Get a quote