1/1
${data.index + 1}/${data.total}
Description
Part Number: 3051CD3A02A1BS5I1M5C1Q4
Ordering Information
- Model: 3051C1 – Coplanar Pressure Transmitter
- Measurement type: D – Differential
- Pressure range: 3 – -1000 to 1000 inH20 (-621,60 to 621,60 mbar)
- Transmitter output: A2 – 4-20 mA with Digital Signal Based on HART Protocol
- Materials of construction: 0 – Alternate Process Connection
- Isolating diaphragm: 23 – 316L SST
- O-Ring: A – Glass-filled PTFE
- Sensor: 1 – Silicone
- B – [Housing material] Aluminium; [Conduit entry size] M20 x 1.5
- Manifold assembly4: S5 – Assemble to Rosemount 305 Integral Manifold
- Product certifications: I15 – ATEX Intrinsic Safety and Dust
- Display and interface options: M5 – LCD Display
- Software configuration: C16 – Custom Software Configuration (completed CDS 00806-0100-4007 for wired and 00806-0100-4100 for Wireless required with order)
- Calibration certificate: Q4 – Calibration Certificate
- Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
- Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
- Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
- Assemble-to items are specified separately and require a completed model number.
- Dust approval not applicable to Output Code X.
- Only available with HART 4-20 mA Output (output code A) and Wireless Output (output code X)
Note: This item complete with manifold 0305RC52B11(C305131124).
- Estimated Lead Time: 8 Weeks
- Shipping Weight: 10 Kg