| Brand |
Micro Motion |
|---|
| Mass Flow Accuracy (Liquid) | ±0.15% of rate (standard) ±0.10% of rate (optional) |
| Mass Flow Repeatability (Liquid) | ±0.05% of rate |
| Volume Flow Accuracy (Liquid) | ±0.25% of rate (standard) ±0.15% of rate (optional) |
| Volume Flow Repeatability (Liquid) | ±0.05% of rate |
| Mass Flow Accuracy (Gas) | ±0.50% of rate |
| Mass Flow Repeatability (Gas) | ±0.25% of rate |
| Density Accuracy (Liquid) | ±0.002 g/cm³ (±2.0 kg/m³) (standard) ±0.001 g/cm³ (±1.0 kg/m³) (optional) ±0.0005 g/cm³ (±0.5 kg/m³) (optional) |
| Temperature Accuracy | ±1 °C ±0.5% of reading |
| Sensor Maximum Working Pressure | 1,450 psig (100 barg) |
| Meter Approvals, Calibrations, and Certifications | • CSA • IECEx • ATEX |
Micro Motion H050S Coriolis Meter
| Minimize Variability in Process Control | Superior sensitivity in a compact design |
| Ensure Product Consistency and Quality | Superior density measurement |
| Enable Fast Product Change-Over | Self-draining design and superior temperature stability |
| Choose from Options | Highly polished 316L stainless steel with a surface finish up to 15 Ra |
| Gain Real-Time and In-Process Measurement Integrity | Smart Meter Verification |
| Realize Superior Two-Phase Flow Capabilities | For batching, loading, and entrained air applications from compact, hygienic SST transmitter housings |
| Broad Range of Meter Approvals and Certifications | Includes CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR |