1/1
${data.index + 1}/${data.total}
Description
| Brand |
Micro Motion |
|---|
| Micro Motion F050P Coriolis Meter | 1/2 Inch (DN15), 316L Stainless Steel, High Pressure |
| Mass Flow Accuracy (Liquid) | ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional) |
| Mass Flow Repeatability (Liquid) | ±0.050% of rate |
| Volume Flow Accuracy (Liquid) | ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional) |
| Volume Flow Repeatability (Liquid) | ±0.050% of rate |
| Mass Flow Accuracy (Gas) | ±0.5% of rate |
| Mass Flow Repeatability (Gas) | ±0.25% of rate |
| Density Accuracy (Liquid) | ±0.002 g/cm³ (2.0 kg/m³) (standard), ±0.001 g/cm³ (1.0 kg/m³) (optional) |
| Temperature Accuracy | ±1 °C ±0.5% of reading |
| Sensor Maximum Working Pressure | 5,000 psig (344 barg) |
| Meter Approvals, Calibrations, and Certifications | • UL • CSA • IECEx • NEPSI • ATEX • Ingress Protection • EMC effects |
| Micro Motion 2500 Compact Control Room Multivariable Flow and Density Transmitter | |
| Output Variables | • Mass & Volume Flow • Net Product Content / Flow • Temperature • Density • Concentration |
| Local Display | None |
| Power | • Minimum 19.2 to 28.8 VDC • 6.3 watts • Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements |
| Input/Output Signals | • One active 4–20 mA output • One active frequency output HART Bell 202 signal is superimposed on the primary milliamp output |
| Mounting Options | Mounted on 35 mm rail (rail must be grounded) |
| Application Types | • Continuous Process Control • Two-Phase Flow/Entrained Gas • Meter Verification |
| Hazardous Approvals | Suitable for non-hazardous environments only |
| Micro Motion F050P Coriolis Meter | 1/2 Inch (DN15), 316L Stainless Steel, High Pressure |
| Measurement Capability | Highly accurate mass volume flow and density measurement in compact, drainable design |
| Materials Available | 316L Stainless Steel and C-22 nickel alloy in all sizes |
| Additional Features | Available with rupture disk or purge fitting case |
| Diagnostics | Extensive process and meter diagnostics with on-board historian and logging |
| Certifications | Broad range of meter approvals including: CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, NAMUR |
| Custody Transfer Approvals | MID OIML R 117, National Type Evaluation Program (NTEP), Measurement Canada, INMETRO Brazil |
| Response Rates | Fastest response rates and accurate batch and process measurement with MVD transmitter technology |
| Integrity Assurance | Real-time and in-process measurement integrity assurance with Smart Meter Verification |
| 3D Model Interaction | Interact with our 3D model to learn more about our F-Series Coriolis Flow and Density Meters |
| Micro Motion 2500 Compact Control Room Multivariable Flow and Density Transmitter | |
| Wiring Cost Savings | Cut wiring expenses with remote-mount transmitter using 35 mm DIN rail |
| Space Requirement | Easily fits in control rooms – only 0.03 ft³ space requirement versus 1.0 ft³ typically for Coriolis transmitters |
| Configuration | Simplified configuration with a four-wire connection to sensors for power and signal |
| Performance Diagnostics | Diagnose performance under entrained gas and batching from empty applications with MVD digital processing |
| Integrity Assurance | Real-time and in-process measurement integrity assurance with Smart Meter Verification |